DDM-DS11
with differential pressure gauge DS11
optionally up to two microswitches
installation between flanges as per DIN EN 1092-1, internal and external threads as per DIN EN ISO 228 or with pipe union as per ISO 7-1
one device for all installation situations and flow directions
suitable for liquids and gases
no moving parts, wear-free
calibration for standard measuring ranges or as per customer specification
metering range 1:6
accuracy 5% FS
Design and applications
The DDM-DS11 metering orifice measures and monitors the flow rate of liquids.
The device works according to the principle of differential pressure.
At the orifice, a differential pressure drop occurs, which is square proportional to the volume flow rate passing the conduit.
The user mounts the orifice between flanges or with Rp pipe unions into the conduit. The unimpeded, straight tube length has to be 6 DN before and 4 DN behind the mounting position.
The DS11 gauge contains a rugged and uncomplicated diaphragm system. The differential pressure generates a unilateral force at the membrane which moves the diaphragm system against the measuring range springs. A centre-mounted tappet transfers motion of the diaphragm system to indicator movement and to initiating elements of the microswitches. Due to the completely mechanical functionality, no external power supply is needed. The applications of DDM-DS11 are engineering and process technology such as the monitoring of coolant streams in plants.
The display pressure gauge can be equipped with one or with two microswitches.
Downloads
Differential pressure flow meters
DDM
DDM-DS11
DDM-EM
DDW-DS31
SMB